Temperatūras testa kameraCTS
TSR-30/1000
Temperatūras testa kamera
CTS
TSR-30/1000
Stāvoklis
Lietots
Atrašanās vieta
Borken 

Rādīt attēlus
Rādīt karti
Dati par iekārtu
Cena un atrašanās vieta
- Atrašanās vieta:
- Einsteinstraße 8a, 46325 Borken, DE
Zvanīt
Piedāvājuma informācija
- Ieraksta ID:
- A14926978
- Atsauces Nr.:
- 23988
- Pēdējoreiz atjaunots:
- 15.11.2460630
Apraksts
CTS Type: TSR-30/1000
Water-cooled
The model designation for the CTS cabinet series is structured as follows:
Example: Type TSR-30/1000
1) T = Temperature
2) S = Stress Screening
3) R = External conditioning
4) -30 = Lower temperature limit: -30°C
5) 1000 = Test chamber volume: 1000 liters
Technical specifications:
A) TSR-30/1000 Base unit without hose connections (i.e., for use as a standalone temperature test cabinet)
Temperature tests:
Temperature range: -40°C to +180°C
End temperature: -45°C
Temperature deviation: ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5:
Heating: 6.0 K/min
Cooling: 5.0 K/min
Gsdpfxsrivfcs Acuobu
Radiant heat output:
Approx. 5000 W at +20°C
Approx. 4200 W at ±0°C
Approx. 3000 W at -20°C
Technical specifications based on ambient temperature of +25°C, nominal voltage 400V, without test specimen, without radiant heat, and without additional equipment.
Airflow rate: approx. 2000 m³/h
B) TSR-30/1000 Base unit with hose connections (for connection to a customer-supplied external test chamber)
Temperature tests:
Temperature range: -30°C to +170°C
Temperature deviation: ≤ ±0.1 to 0.5 K over time
Average temperature change rate (measured in a closed circuit):
Heating: 4.0 K/min
Cooling: 4.0 K/min
(in the range from +150°C to -10°C)
Specifications based on an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without radiant heat, and without additional equipment, measured in closed circuit.
Note: The customer-provided external test chamber must be completely sealed and adequately insulated; all ports must be optimally sealed on site.
Dimensions:
Test volume: 1000 liters
Recirculating air connection: Ø 200 mm
Test chamber dimensions: Height 900 mm, Width 1000 mm, Depth 1100 mm
External dimensions: Height 1950 mm, Width 1270 mm, Depth 2245 mm
Technical features:
Refrigeration unit:
- Water-cooled, low-noise, fully hermetic
- Infinitely variable power adjustment via electronic monitoring and control system
- Environmentally friendly refrigerant R404A
Door:
- Fully opening door, left hinge
- One-hand operation, lockable
Insert rack:
- Stainless steel, support surface 970 x 980 mm
- Max. load per rack: 35 kg
- Max. total load with maximum rack configuration: 100 kg
Test chamber lighting: Halogen lamp 20 W, 12 V
Control system:
- 32-bit controller
- LCD control panel
Operating data:
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Nominal power: 13.3 kW
Protection class: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 850 kg
For your safety as a buyer, the following is ensured prior to delivery:
1. Functional check and replacement of necessary components
2. New refill with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in technical data! Specifications are subject to change.)
Further questions can be answered by phone.
Sludinājums tika tulkots automātiski, tāpēc tajā varētu būt dažas tulkošanas kļūdas.
Water-cooled
The model designation for the CTS cabinet series is structured as follows:
Example: Type TSR-30/1000
1) T = Temperature
2) S = Stress Screening
3) R = External conditioning
4) -30 = Lower temperature limit: -30°C
5) 1000 = Test chamber volume: 1000 liters
Technical specifications:
A) TSR-30/1000 Base unit without hose connections (i.e., for use as a standalone temperature test cabinet)
Temperature tests:
Temperature range: -40°C to +180°C
End temperature: -45°C
Temperature deviation: ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5:
Heating: 6.0 K/min
Cooling: 5.0 K/min
Gsdpfxsrivfcs Acuobu
Radiant heat output:
Approx. 5000 W at +20°C
Approx. 4200 W at ±0°C
Approx. 3000 W at -20°C
Technical specifications based on ambient temperature of +25°C, nominal voltage 400V, without test specimen, without radiant heat, and without additional equipment.
Airflow rate: approx. 2000 m³/h
B) TSR-30/1000 Base unit with hose connections (for connection to a customer-supplied external test chamber)
Temperature tests:
Temperature range: -30°C to +170°C
Temperature deviation: ≤ ±0.1 to 0.5 K over time
Average temperature change rate (measured in a closed circuit):
Heating: 4.0 K/min
Cooling: 4.0 K/min
(in the range from +150°C to -10°C)
Specifications based on an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without radiant heat, and without additional equipment, measured in closed circuit.
Note: The customer-provided external test chamber must be completely sealed and adequately insulated; all ports must be optimally sealed on site.
Dimensions:
Test volume: 1000 liters
Recirculating air connection: Ø 200 mm
Test chamber dimensions: Height 900 mm, Width 1000 mm, Depth 1100 mm
External dimensions: Height 1950 mm, Width 1270 mm, Depth 2245 mm
Technical features:
Refrigeration unit:
- Water-cooled, low-noise, fully hermetic
- Infinitely variable power adjustment via electronic monitoring and control system
- Environmentally friendly refrigerant R404A
Door:
- Fully opening door, left hinge
- One-hand operation, lockable
Insert rack:
- Stainless steel, support surface 970 x 980 mm
- Max. load per rack: 35 kg
- Max. total load with maximum rack configuration: 100 kg
Test chamber lighting: Halogen lamp 20 W, 12 V
Control system:
- 32-bit controller
- LCD control panel
Operating data:
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Nominal power: 13.3 kW
Protection class: IP 22
Sound pressure level: < 60 dB(A)
Weight: approx. 850 kg
For your safety as a buyer, the following is ensured prior to delivery:
1. Functional check and replacement of necessary components
2. New refill with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in technical data! Specifications are subject to change.)
Further questions can be answered by phone.
Sludinājums tika tulkots automātiski, tāpēc tajā varētu būt dažas tulkošanas kļūdas.
Piegādātājs
Piezīme: Reģistrējieties bez maksas vai piesakieties, lai iegūtu visu informāciju.
Iesniegt pieprasījumu
Tālrunis & Fakss
+49 2861 ... sludinājumi
Jūsu sludinājums ir veiksmīgi dzēsts
Radās kļūda