Weiss
Model: WT3-1000/40
Weiss Temperature Test Chamber with S!MCON / 32-control, Water-cooled
Control Unit: "Touch Panel"
All control and operation commands can be executed on the "Touch Panel" control unit simply by touching the function icons.
Adjustable Feet
To compensate for floor unevenness and ensure sufficient ventilation of the machine section, the test chamber comes equipped with adjustable feet.
Feedthroughs
The chamber is fitted with feedthroughs on the right and left sides. These allow measuring cables and test equipment to be routed into the test chamber.
Standard feedthroughs installed:
R1: nominal width 125 mm
L1: nominal width 50 mm
Test Chamber Volume: approx. 990 liters
Test Chamber Dimensions: Height 950 mm, Width 1100 mm, Depth 950 mm
External Dimensions: Height 2000 mm, Width 1415 mm, Depth 2105 mm
Temperature Test Data:
Temperature Range: -40 to +180 °C
Temperature Deviation over Time at Workspace Center: ± 0.1 to ± 0.5 K
Spatial Temperature Deviation: ± 0.5 to ± 1.5 K
Temperature Change Rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Maximum Heat Compensation: 4500 W
Operational Data:
Iedpfx Aothhw Ash Retf
Test Chamber Lighting: Halogen bulbs 2x 24V, 50W
Rated Voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated Current: 22.0 A Rated Power: 11.5 kW
Fuse (on-site): 32 A slow-blow
Sound Pressure Level approx.:
Measured at 1m distance from the front, 1m height: 56 dB(A)
Refrigerant: R-404A
Weight: 840 kg
For your safety as a buyer, please note the following:
The following actions are performed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical data are subject to change and error!)
We are happy to answer further questions by phone.
Sludinājums tika automātiski tulkots. Iespējamas tulkošanas kļūdas.
Model: WT3-1000/40
Weiss Temperature Test Chamber with S!MCON / 32-control, Water-cooled
Control Unit: "Touch Panel"
All control and operation commands can be executed on the "Touch Panel" control unit simply by touching the function icons.
Adjustable Feet
To compensate for floor unevenness and ensure sufficient ventilation of the machine section, the test chamber comes equipped with adjustable feet.
Feedthroughs
The chamber is fitted with feedthroughs on the right and left sides. These allow measuring cables and test equipment to be routed into the test chamber.
Standard feedthroughs installed:
R1: nominal width 125 mm
L1: nominal width 50 mm
Test Chamber Volume: approx. 990 liters
Test Chamber Dimensions: Height 950 mm, Width 1100 mm, Depth 950 mm
External Dimensions: Height 2000 mm, Width 1415 mm, Depth 2105 mm
Temperature Test Data:
Temperature Range: -40 to +180 °C
Temperature Deviation over Time at Workspace Center: ± 0.1 to ± 0.5 K
Spatial Temperature Deviation: ± 0.5 to ± 1.5 K
Temperature Change Rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Maximum Heat Compensation: 4500 W
Operational Data:
Iedpfx Aothhw Ash Retf
Test Chamber Lighting: Halogen bulbs 2x 24V, 50W
Rated Voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated Current: 22.0 A Rated Power: 11.5 kW
Fuse (on-site): 32 A slow-blow
Sound Pressure Level approx.:
Measured at 1m distance from the front, 1m height: 56 dB(A)
Refrigerant: R-404A
Weight: 840 kg
For your safety as a buyer, please note the following:
The following actions are performed on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical data are subject to change and error!)
We are happy to answer further questions by phone.
Sludinājums tika automātiski tulkots. Iespējamas tulkošanas kļūdas.
Nosūtīt pieprasījumu
Tālrunis & Fakss
+49 2861 ... sludinājumi
Šie sludinājumi varētu arī jūs ieinteresēt.
Mazā sludinājuma
Kreuztal
1 266 km
Vertikālais apstrādes centrs
DMG Mori SeikiDMU 50 ecoline
DMG Mori SeikiDMU 50 ecoline
Mazā sludinājuma
Borken
1 273 km
Klimata testēšanas kamera ar mitrumu
WeissSB2/500/80 -75°C bis +180°C
WeissSB2/500/80 -75°C bis +180°C
Mazā sludinājuma
Vācija
1 120 km
Pacelšanas un novietošanas mašīna
NeoDenS1
NeoDenS1
Mazā sludinājuma
Borken
1 273 km
Šeikera sistēma ar pastiprinātāju
LDSV895-440 HBT900C + SPA50K
LDSV895-440 HBT900C + SPA50K
Mazā sludinājuma
Vācija
1 120 km
Optiskā mērīšanas sistēma
KeyenceLS-9000
KeyenceLS-9000
Mazā sludinājuma
Borken
1 273 km
Temperatūras testēšanas kamera 1000 litri
CTS - 70°C bis +180°CTS -70/1000-10 bis ca.10 K/min
CTS - 70°C bis +180°CTS -70/1000-10 bis ca.10 K/min
Mazā sludinājuma
Vācija
1 120 km
Pacelšanas un novietošanas mašīna
EssemtecFLX2011-LV
EssemtecFLX2011-LV
Mazā sludinājuma
Borken
1 277 km
LDS V 726 kratīšanas sistēma ar pastiprinātāju
LDSLDS PA2000 LDS 726
LDSLDS PA2000 LDS 726
Mazā sludinājuma
Borken
1 273 km
Klimata testa kamera ar mitrumu 34 litri
VötschVCL 7003 -70°C bis +180°C
VötschVCL 7003 -70°C bis +180°C
Mazā sludinājuma
Borken
1 273 km
Temperatūras testa kamera 680 litri
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Jūsu sludinājums ir veiksmīgi dzēsts
Radās kļūda