Klimata skapis ar mitruma kontroli, 34 litriWeiss
WKL 34/40 -40...+150°C
Klimata skapis ar mitruma kontroli, 34 litri
Weiss
WKL 34/40 -40...+150°C
Stāvoklis
Lietots
Atrašanās vieta
Borken 

Rādīt attēlus
Rādīt karti
Dati par iekārtu
- Mašīnas apraksts:
- Klimata skapis ar mitruma kontroli, 34 litri
- Ražotājs:
- Weiss
- Modelis:
- WKL 34/40 -40...+150°C
- Stāvoklis:
- ļoti labs (lietots)
Cena un atrašanās vieta
- Atrašanās vieta:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Zvanīt
Piedāvājuma informācija
- Ieraksta ID:
- A20492700
- Atsauces Nr.:
- 24870
- Pēdējoreiz atjaunots:
- 10.11.2460990
Apraksts
Weiss Type: WKL 34/40 Weiss Climate Chamber, Air-cooled Temperature Range: -40°C to 150°C Chamber Volume: 34 liters Built-in feedthroughs in standard configuration: R1 NW 50 mm, L1 NW 120 mm Internal dimensions: Height 310 mm Width 324 mm Depth 300 mm External dimensions: Height 1740 mm Width 630 mm Depth 970 mm Specifications for temperature tests: Temperature range: -40 to +150 °C Temperature deviations under steady state (according to IEC 60068-3-5) Temporal temperature fluctuation at the center of the usable space: ± 0.3 to ± 1 K, ± 1 to ± 2 K Spatial temperature deviation (corresponds to temperature gradient): 2 to 4 Temperature change rate (according to IEC 60068-3-5): Heating 2.5 K/min, Cooling 3.5 K/min Heat compensation max. 800 W Specifications for climate tests: Temperature range: +10 to +95 °C Humidity range: 10 to 98 % RH Temperature and humidity deviations (under steady state, as per IEC 60068-3-5) Temporal temperature fluctuation at the center of the usable space: ± 0.3 to ± 0.5 K Spatial temperature deviation: ± 0.5 to ± 1.5 (corresponds to temperature gradient) 1 to 3 Temporal humidity fluctuation at the center of the usable space: ± 3 to ± 5 % RH Operating data: Test space lighting: halogen bulb 12V, 20W Rated voltage 1/N / PE AC 230 V ± 10 % 50 Hz Rated power 1.8 kW Rated current 8.0 A On-site fuse 16A slow Heat emission for air-cooled test chambers Max. heat emission to environment: 800 W Refrigerant: R-404A Weight: 110 kg Important note: "The table shown in the photos is not included in the sale." Information for your safety as buyer: The following procedures are carried out on chambers offered by us prior to delivery: 1. Functional check and replacement of necessary components 2. If necessary, refilling with legally compliant refrigerant 3. Leak test with certificate 4. After successful inspection, a documented test run is performed Condition: used Scope of delivery: (see picture) (Specifications and data subject to change and errors reserved!) For further questions, please feel free to contact us by phone.
Dsdpfjxvpp Rox Abpowd
Sludinājums tika tulkots automātiski, tāpēc tajā varētu būt dažas tulkošanas kļūdas.
Dsdpfjxvpp Rox Abpowd
Sludinājums tika tulkots automātiski, tāpēc tajā varētu būt dažas tulkošanas kļūdas.
Piegādātājs
Piezīme: Reģistrējieties bez maksas vai piesakieties, lai iegūtu visu informāciju.
Iesniegt pieprasījumu
Tālrunis & Fakss
+49 2861 ... sludinājumi
Jūsu sludinājums ir veiksmīgi dzēsts
Radās kļūda