Klimata pārbaudes kamera Temp. -70 līdz 180°CWeiss explosionsgeschützt
WK-600/70 (I)-(II) 2 G EEx
Klimata pārbaudes kamera Temp. -70 līdz 180°C
Weiss explosionsgeschützt
WK-600/70 (I)-(II) 2 G EEx
Stāvoklis
Lietots
Atrašanās vieta
Borken 

Rādīt attēlus
Rādīt karti
Dati par iekārtu
- Mašīnas apraksts:
- Klimata pārbaudes kamera Temp. -70 līdz 180°C
- Ražotājs:
- Weiss explosionsgeschützt
- Modelis:
- WK-600/70 (I)-(II) 2 G EEx
- Stāvoklis:
- ļoti labs (lietots)
Cena un atrašanās vieta
- Atrašanās vieta:
- Einsteinstraße 8a, 46325 Borken, DE
Zvanīt
Piedāvājuma informācija
- Ieraksta ID:
- A18631321
- Atsauces Nr.:
- 20744
- Pēdējoreiz atjaunots:
- 04.3.2460739
Apraksts
Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss climate test chamber, water-cooled
(Test compartment with explosion protection)
INERTIZATION WITH NITROGEN / EXPLOSION-PROTECTED TEST COMPARTMENT
Technical data:
Test chamber model: WK-600/70 (I)-(II) 2 G EEx
External dimensions including hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Godpfx Asv Ewy Hscujbu
Test chamber volume: approx. 600 liters
Refrigeration / Heating operation: -70 to +180°C
Climatic operation: 10 – 95°C
Humidity: 10...98 % r. h.
Temperature change rate:
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
External fuse required: 32 A slow-blow
Permissible specimen weight
Total load for grid shelves: 80 kg
Test chamber floor: 80 kg, Insert rack: 40 kg
Weight: 800 kg
Refrigerants: R 404A / R 23
(Evaporator of the air conditioning system has been renewed)
Important safety information for the buyer!
The following steps are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful checks, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and error!)
For further questions, we will be happy to answer you by phone.
Sludinājums tika tulkots automātiski, tāpēc tajā varētu būt dažas tulkošanas kļūdas.
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss climate test chamber, water-cooled
(Test compartment with explosion protection)
INERTIZATION WITH NITROGEN / EXPLOSION-PROTECTED TEST COMPARTMENT
Technical data:
Test chamber model: WK-600/70 (I)-(II) 2 G EEx
External dimensions including hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Godpfx Asv Ewy Hscujbu
Test chamber volume: approx. 600 liters
Refrigeration / Heating operation: -70 to +180°C
Climatic operation: 10 – 95°C
Humidity: 10...98 % r. h.
Temperature change rate:
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
External fuse required: 32 A slow-blow
Permissible specimen weight
Total load for grid shelves: 80 kg
Test chamber floor: 80 kg, Insert rack: 40 kg
Weight: 800 kg
Refrigerants: R 404A / R 23
(Evaporator of the air conditioning system has been renewed)
Important safety information for the buyer!
The following steps are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful checks, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and error!)
For further questions, we will be happy to answer you by phone.