Moduļu membrānas filtrēšanas iekārtaGEA
Membrane Skid up to 6.25 m³/h
Moduļu membrānas filtrēšanas iekārta
GEA
Membrane Skid up to 6.25 m³/h
Ražošanas gads
2013
Stāvoklis
Lietots
Atrašanās vieta
Liestal 

Dati par iekārtu
- Iekārtas apzīmējums:
- Moduļu membrānas filtrēšanas iekārta
- Ražotājs:
- GEA
- Modelis:
- Membrane Skid up to 6.25 m³/h
- Ražošanas gads:
- 2013
- Stāvoklis:
- ļoti labs (lietots)
Cena un atrašanās vieta
- Atrašanās vieta:
- 4410 Liestal, Schweiz

Zvanīt
Piedāvājuma informācija
- Sludinājuma ID:
- A18024946
- Atjaunināšana:
- pēdējo reizi 21.02.2025
Apraksts
GEA Modular Membrane Filtration System up to 6.25 m³/h, in excellent condition and barely used. This equipment was used for just two validation batches, and after that has been in storage. It is currently equipped with spiral-wound nanofiltration membranes but other membrane types can be used for microfiltration (MF), ultrafiltration (UF), etc.
The complete original manufacturer documentation is included in digital format, comprising the operating manual, process flow charts, wiring diagrams, certificates, inspection reports, and other relevant technical documentation.
The system is designed to process a maximum volume of approximately 100 m³ of product (feed) per day. An average feed flow rate of approximately 4 to 6 m³/h is assumed under the “16/4” or “20/4” operating regime (Explanation: “20/4” corresponds to 20 hours of filtration operation / 4 hours of CIP cleaning).
If, at a later stage, the daily processing capacity needs to be increased or the installed membrane surface becomes insufficient due to unforeseeable fouling effects, two empty slots are provided for retrofitting additional membrane housings. The piping and recirculation pump are already prepared for such an expansion.
The membrane unit is designed for a semi-automatic cleaning-in-place (CIP) procedure. The system includes the required valves for internal circulation of cleaning solutions, followed by system flushing.
Specifications
- Feed volume: 400 - 500 m³/week
- Feed volume: 80 - 100 m³/day
- Feed volume: 4.0 - 6.25 m³/h
- Production time: 16 - 20 h/day
- Operating temperature: 35 to max. 65 °C
Consumption
- Power supply (pumps): 3 x 400 V, 50 Hz
- Installed power: approx. 65 kW
- Electric power consumption: 53.1 kW/h
- Compressed air: 6 bar, oil- and water-free
- Steam: 6 bar (max.)
- Seal water: approx. 75 - 150 l/h
- CIP water: approx. 19 m³/h
- CIP water per cycle: 6 m³/CIP
- Steam consumption per cycle: 100 kg/CIP
- CIP chemicals: (e.g., membrane cleaner, acid, alkali, preservative, biocide)
Limits
- Max. operating temperature: 65 °C
- Max. operating pressure: 30 bar
- pH range for feed water:
- Maximum: pH 10.0
- Minimum: pH 2.0
Cleaning-in-Place (CIP)
- Max. temperature: 85 °C
- Max. pressure: 10 bar
Ijdpevhctwofx Amiotg
- pH limits (for up to 30 minutes):
- Maximum: pH 10.5
- Minimum: pH 2.0
The complete original manufacturer documentation is included in digital format, comprising the operating manual, process flow charts, wiring diagrams, certificates, inspection reports, and other relevant technical documentation.
The system is designed to process a maximum volume of approximately 100 m³ of product (feed) per day. An average feed flow rate of approximately 4 to 6 m³/h is assumed under the “16/4” or “20/4” operating regime (Explanation: “20/4” corresponds to 20 hours of filtration operation / 4 hours of CIP cleaning).
If, at a later stage, the daily processing capacity needs to be increased or the installed membrane surface becomes insufficient due to unforeseeable fouling effects, two empty slots are provided for retrofitting additional membrane housings. The piping and recirculation pump are already prepared for such an expansion.
The membrane unit is designed for a semi-automatic cleaning-in-place (CIP) procedure. The system includes the required valves for internal circulation of cleaning solutions, followed by system flushing.
Specifications
- Feed volume: 400 - 500 m³/week
- Feed volume: 80 - 100 m³/day
- Feed volume: 4.0 - 6.25 m³/h
- Production time: 16 - 20 h/day
- Operating temperature: 35 to max. 65 °C
Consumption
- Power supply (pumps): 3 x 400 V, 50 Hz
- Installed power: approx. 65 kW
- Electric power consumption: 53.1 kW/h
- Compressed air: 6 bar, oil- and water-free
- Steam: 6 bar (max.)
- Seal water: approx. 75 - 150 l/h
- CIP water: approx. 19 m³/h
- CIP water per cycle: 6 m³/CIP
- Steam consumption per cycle: 100 kg/CIP
- CIP chemicals: (e.g., membrane cleaner, acid, alkali, preservative, biocide)
Limits
- Max. operating temperature: 65 °C
- Max. operating pressure: 30 bar
- pH range for feed water:
- Maximum: pH 10.0
- Minimum: pH 2.0
Cleaning-in-Place (CIP)
- Max. temperature: 85 °C
- Max. pressure: 10 bar
Ijdpevhctwofx Amiotg
- pH limits (for up to 30 minutes):
- Maximum: pH 10.5
- Minimum: pH 2.0
Piegādātājs
Piezīme: Reģistrējieties bez maksas vai piesakieties, lai iegūtu visu informāciju.
Reģistrēts kopš: 2023
10 Sludinājumi tiešsaistē
Nosūtīt pieprasījumu
Tālrunis & Fakss
+41 61 50... sludinājumi
Šie sludinājumi varētu arī jūs ieinteresēt.
Mazā sludinājuma
Dinkelscherben
1 339 km
Plakanas lentes konveijers FDA pārtikas atbilstība
die magnetrofis GmbH & Co. KGFlachförderband FDA
die magnetrofis GmbH & Co. KGFlachförderband FDA
Mazā sludinājuma
Babenhausen
1 288 km
Krējuma plīts
MicaCK 60
MicaCK 60
Mazā sludinājuma
Thisted
963 km
Rotējošais sūknis JEC
JEC-PumpZF -120-021
JEC-PumpZF -120-021
Mazā sludinājuma
Dānija
927 km
Piena un piena produktu ražošana
Alfa Laval BactofugeMRPX 418SGV-34C
Alfa Laval BactofugeMRPX 418SGV-34C
Mazā sludinājuma
Vācija
1 120 km
Piena pildīšanas līnija
ElopakPS 50
ElopakPS 50
Mazā sludinājuma
Kreuzau
1 363 km
Maisīšanas un jaukšanas iekārta
StephanUMC 12
StephanUMC 12
Mazā sludinājuma
Suffolk
1 614 km
Maisiņu pildīšanas iekārta
Toyo JidokiTT-8
Toyo JidokiTT-8
Mazā sludinājuma
Menslage
1 166 km
ALWID ATEX uzpildes līnija (2021)
ALWIDAbfülllinie
ALWIDAbfülllinie
Mazā sludinājuma
Thisted
963 km
Piena un piena ražošana
APVType PCI-UF 50-100
APVType PCI-UF 50-100
Mazā sludinājuma
Vācija
1 120 km
Ganāmpulka vagonkrāsns
NaberthermW 1000/A
NaberthermW 1000/A
Jūsu sludinājums ir veiksmīgi dzēsts
Radās kļūda