Klimata testēšanas kamera 1000 litriCTS
C-55/1000 Li -50°C bis 100°C
Klimata testēšanas kamera 1000 litri
CTS
C-55/1000 Li -50°C bis 100°C
Stāvoklis
Lietots
Atrašanās vieta
Borken 

Rādīt attēlus
Rādīt karti
Dati par iekārtu
- Mašīnas apraksts:
- Klimata testēšanas kamera 1000 litri
- Ražotājs:
- CTS
- Modelis:
- C-55/1000 Li -50°C bis 100°C
- Stāvoklis:
- ļoti labs (lietots)
Cena un atrašanās vieta
- Atrašanās vieta:
- Einsteinstraße 8a, 46325 Borken, DE
Zvanīt
Piedāvājuma informācija
- Ieraksta ID:
- A17851641
- Atsauces Nr.:
- 24459
- Pēdējoreiz atjaunots:
- 28.11.2460643
Apraksts
CTS Climate Test Chamber C-55/1000 Li Water-Cooled
Temperature range: -50°C to +100°C
Humidity range: 5 to 95% r.h.
Dew point range: 5°C to +78°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Rated current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The model designation of the CTS chamber series is as follows:
Example: Type C -55/1000/Li
1) C stands for: Climate
2) -55 stands for: minimum temperature -55°C
3) 1000 stands for: 1000 liters test chamber volume
4) Li stands for: special equipment for testing with lithium-ion batteries
Control:
32-bit controller
LCD control panel
Digital display of set and actual values
Numerical entry of setpoints
Plain text error messages
Ethernet interface
RS 232 interface
Free switching channels for external test item control
Test Chamber Lighting:
Energy-efficient, high-intensity LED light bar mounted on the door
Shelf:
Stainless steel, support surface 970 x 980 mm
Max. load per shelf: 35 kg
Total load with maximum shelves: 100 kg
Feedthroughs:
1a Feedthrough NW50
1b Feedthrough 2x NW125
1c Feedthrough 2x Rp 3 1/4”
Dsdpfxsva Hi Ho Abpswc
for Minimax
Technical Performance Data:
Temperature Testing:
Temperature range: -50°C to +100°C
Temporal temperature deviation: ≤ ±0.3 K
Temperature change rate acc. to IEC 60068-3-5:
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation:
Approx. 4000 W at +20°C
Approx. 2200 W at -40°C
Climate Testing:
Temperature range: +5°C to +95°C
Humidity range: 5% to 95% relative humidity
Dew point range: +5°C to 78°C
Temporal temperature deviation: ≤ ±1.0 K
Temporal humidity deviation: ≤ ±3.0% r.h.
Technical data refer to an ambient temperature of +25°C,
rated voltage 400V, without test specimen, without heat compensation and without additional equipment.
Options may affect performance data.
Dimensions:
Test volume: 1000 liters
Test chamber dimensions: Height approx. 1000 mm, Width approx. 860 mm, Depth approx. 1100 mm
External dimensions: Height approx. 1950 mm, Width approx. 1270 mm, Depth approx. 1900 mm
Operating Data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated current: 18 A
Rated power: 9.5 kW
Protection class: IP 54
Sound pressure level: < 58 dB(A)
(measured according to DIN EN ISO 3744 at a distance of 1m from the front)
Weight: approx. 1000 kg
Heat emission to installation area: 10.4 kW
Refrigeration Unit:
Water-cooled, low-noise, fully hermetic
Infinitely variable power adjustment via electronic monitoring and control system,
environmentally friendly refrigerants R404A/R23
Important Information for Buyers – For Your Safety!
The following checks are carried out on our offered chambers in advance:
1. Function test and replacement of necessary components
2. New filling with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in technical data and specifications!)
Further questions can be answered by phone.
Sludinājums tika tulkots automātiski, tāpēc tajā varētu būt dažas tulkošanas kļūdas.
Temperature range: -50°C to +100°C
Humidity range: 5 to 95% r.h.
Dew point range: 5°C to +78°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Rated current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The model designation of the CTS chamber series is as follows:
Example: Type C -55/1000/Li
1) C stands for: Climate
2) -55 stands for: minimum temperature -55°C
3) 1000 stands for: 1000 liters test chamber volume
4) Li stands for: special equipment for testing with lithium-ion batteries
Control:
32-bit controller
LCD control panel
Digital display of set and actual values
Numerical entry of setpoints
Plain text error messages
Ethernet interface
RS 232 interface
Free switching channels for external test item control
Test Chamber Lighting:
Energy-efficient, high-intensity LED light bar mounted on the door
Shelf:
Stainless steel, support surface 970 x 980 mm
Max. load per shelf: 35 kg
Total load with maximum shelves: 100 kg
Feedthroughs:
1a Feedthrough NW50
1b Feedthrough 2x NW125
1c Feedthrough 2x Rp 3 1/4”
Dsdpfxsva Hi Ho Abpswc
for Minimax
Technical Performance Data:
Temperature Testing:
Temperature range: -50°C to +100°C
Temporal temperature deviation: ≤ ±0.3 K
Temperature change rate acc. to IEC 60068-3-5:
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation:
Approx. 4000 W at +20°C
Approx. 2200 W at -40°C
Climate Testing:
Temperature range: +5°C to +95°C
Humidity range: 5% to 95% relative humidity
Dew point range: +5°C to 78°C
Temporal temperature deviation: ≤ ±1.0 K
Temporal humidity deviation: ≤ ±3.0% r.h.
Technical data refer to an ambient temperature of +25°C,
rated voltage 400V, without test specimen, without heat compensation and without additional equipment.
Options may affect performance data.
Dimensions:
Test volume: 1000 liters
Test chamber dimensions: Height approx. 1000 mm, Width approx. 860 mm, Depth approx. 1100 mm
External dimensions: Height approx. 1950 mm, Width approx. 1270 mm, Depth approx. 1900 mm
Operating Data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated current: 18 A
Rated power: 9.5 kW
Protection class: IP 54
Sound pressure level: < 58 dB(A)
(measured according to DIN EN ISO 3744 at a distance of 1m from the front)
Weight: approx. 1000 kg
Heat emission to installation area: 10.4 kW
Refrigeration Unit:
Water-cooled, low-noise, fully hermetic
Infinitely variable power adjustment via electronic monitoring and control system,
environmentally friendly refrigerants R404A/R23
Important Information for Buyers – For Your Safety!
The following checks are carried out on our offered chambers in advance:
1. Function test and replacement of necessary components
2. New filling with legally compliant refrigerant if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in technical data and specifications!)
Further questions can be answered by phone.
Sludinājums tika tulkots automātiski, tāpēc tajā varētu būt dažas tulkošanas kļūdas.
Piegādātājs
Piezīme: Reģistrējieties bez maksas vai piesakieties, lai iegūtu visu informāciju.
Iesniegt pieprasījumu
Tālrunis & Fakss
+49 2861 ... sludinājumi
Šie sludinājumi varētu arī jūs ieinteresēt.
mazā sludinājuma

1 273 km
Temperatūras testa kamera 1000 litri
CTST-55/1000 Li -50°C bis 100°C
CTST-55/1000 Li -50°C bis 100°C
Jūsu sludinājums ir veiksmīgi dzēsts
Radās kļūda