- Mašīnas apraksts:
- Maināmas klimata skapī ar mitruma kontroli
- Ražotājs:
- Binder
- Modelis:
- MKF 720 E3.1 -40°C bis 180°C
- Stāvoklis:
- ļoti labs (lietots)
Cena un atrašanās vieta
- Atrašanās vieta:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Zvanīt
Piedāvājuma informācija
- Ieraksta ID:
- A21301667
- Atsauces Nr.:
- 25061
- Pēdējoreiz atjaunots:
- 23.2.2461095
Apraksts
Binder
Model: MKF 720 E3.1
Temperature Cycling Chamber / Climatic Test Chamber
Air-cooled
Temperature range: -40°C to +180°C
Humidity range: 10% RH to 98% RH
The MKF temperature cycling chamber is a specially developed environmental simulation chamber for industrial materials testing and environmental simulation, offering unprecedented performance that far exceeds the capabilities of a standard heat chamber. It is designed to handle all requirements associated with material testing, aging, and stress tests.
TECHNICAL DATA:
Housing dimensions:
Width: 1615 mm | Height: 2005 mm | Depth: 1230 mm
Internal dimensions:
Width: 1200 mm | Height: 1020 mm | Depth: 600 mm
Chamber volume: 734 liters
Net weight (empty): 590 kg
Maximum total load: 160 kg
Maximum load per shelf: 40 kg
Temperature Performance:
Temperature range: -40°C...180°C
Temporal temperature deviation: 0.1...0.5 ± K
Spatial temperature deviation: 0.1...1.8 ± K
Average heating rate according to IEC 60068-3-5: 4.8 K/min
Average cooling rate according to IEC 60068-3-5: 4.8 K/min
Max. heat compensation: 6500 W
Climatic Performance:
Temperature range: 10...95°C
Humidity range: 10...98% RH
Temporal temperature deviation (setpoint dependent): 0.2...1.5 ± K
Max. heat compensation: 1000 W
Electrical Data:
Rated voltage: 400V 3N~ ±10% 50Hz
Rated power: 11 kW | 19.2 A
Refrigerant: R404A, 5 kg
Important Note:
"The table shown in the photos is not included in the sale."
For your safety as a buyer, please note:
The following procedures are performed in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Lhodpeymcqdjfx Aaqoc
Condition: used
Scope of delivery: (see image)
(Subject to change and errors in technical data. All information without guarantee!)
For further questions, we are happy to assist you by phone.
Sludinājums tika tulkots automātiski, tāpēc tajā varētu būt dažas tulkošanas kļūdas.
Model: MKF 720 E3.1
Temperature Cycling Chamber / Climatic Test Chamber
Air-cooled
Temperature range: -40°C to +180°C
Humidity range: 10% RH to 98% RH
The MKF temperature cycling chamber is a specially developed environmental simulation chamber for industrial materials testing and environmental simulation, offering unprecedented performance that far exceeds the capabilities of a standard heat chamber. It is designed to handle all requirements associated with material testing, aging, and stress tests.
TECHNICAL DATA:
Housing dimensions:
Width: 1615 mm | Height: 2005 mm | Depth: 1230 mm
Internal dimensions:
Width: 1200 mm | Height: 1020 mm | Depth: 600 mm
Chamber volume: 734 liters
Net weight (empty): 590 kg
Maximum total load: 160 kg
Maximum load per shelf: 40 kg
Temperature Performance:
Temperature range: -40°C...180°C
Temporal temperature deviation: 0.1...0.5 ± K
Spatial temperature deviation: 0.1...1.8 ± K
Average heating rate according to IEC 60068-3-5: 4.8 K/min
Average cooling rate according to IEC 60068-3-5: 4.8 K/min
Max. heat compensation: 6500 W
Climatic Performance:
Temperature range: 10...95°C
Humidity range: 10...98% RH
Temporal temperature deviation (setpoint dependent): 0.2...1.5 ± K
Max. heat compensation: 1000 W
Electrical Data:
Rated voltage: 400V 3N~ ±10% 50Hz
Rated power: 11 kW | 19.2 A
Refrigerant: R404A, 5 kg
Important Note:
"The table shown in the photos is not included in the sale."
For your safety as a buyer, please note:
The following procedures are performed in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Lhodpeymcqdjfx Aaqoc
Condition: used
Scope of delivery: (see image)
(Subject to change and errors in technical data. All information without guarantee!)
For further questions, we are happy to assist you by phone.
Sludinājums tika tulkots automātiski, tāpēc tajā varētu būt dažas tulkošanas kļūdas.
Piegādātājs
Piezīme: Reģistrējieties bez maksas vai piesakieties, lai iegūtu visu informāciju.
Reģistrēts kopš: 2012
Iesniegt pieprasījumu
Tālrunis & Fakss
+49 2861 ... sludinājumi
Jūsu sludinājums ir veiksmīgi dzēsts
Radās kļūda